;TECHNICAL DATA
GENERAL DATA
Mains voltage | 230V |
---|---|
Mains voltage tolerance | +/-15% |
Mains frequency | 50-60Hz |
Welding current / Duty cycle [10min/40°C] | 230A / 45% |
Welding current / Duty cycle [10min/40°C] | 205A / 60% |
Welding current / Duty cycle [10min/40°C] | 170A / 100% |
Open-circuit voltage | 97 V |
Degree of protection | IP23 |
;FUNCTIONS
TAC
With TAC, one spot is all it takes for tacking, because the pulsed arc sets the two weld pools in motion, making them jump together in next to no time, to make one single weld-pool. The TAC function is also very useful when welding light-gauge sheets without filler metal.
HF IGNITION
The touchless and gentle high-frequency ignition is the easiest option for igniting the arc.
TOUCHDOWN IGNITION
Touchdown ignition can be used in particular for sensitive application areas. This allows electromagnetic interference, which can occur during HF ignition, to be avoided.